Feeds third-party BBQ probes into a pellet grill's wired probe jacks by presenting the resistance a real PT1000 RTD would show at that temperature. The grill sees an ordinary wired probe, so its display, app, target-temp alarms and Keep Warm all work with no protocol reversing involved. Pluggable probe sources: ThermoWorks RFX (via ThermoWorks Cloud), MEATER (community-derived BLE decode), a synthetic simulator for hardware-free development, and a Combustion stub. Two safety invariants are load-bearing: - Stale, missing or implausible readings drive the channel cold, never hot. A stuck-hot channel could convince the grill a cook finished early. - Unimplemented sources raise rather than returning plausible numbers, since the grill acts on these values. Cloud sources are dated by the cloud's own timestamp rather than by fetch time, because ThermoWorks serves a dead probe's last value with a fresh 200. Co-Authored-By: Claude Opus 5 <[email protected]>
7.6 KiB
Protocol notes
What we know about each probe vendor, and how much to trust it. Everything here is community reverse engineering unless marked otherwise — none of it is vendor documentation except where linked.
MEATER / MEATER+ / MEATER 2 — implemented, unverified
Source: sources/meater.py
Derived from nathanfaber/meaterble and the Home Assistant MEATER BLE work.
| Item | Value |
|---|---|
| Service UUID | a75cc7fc-c956-488f-ac2a-2dbc08b63a04 |
| Temperature char | 7edda774-045e-4bbf-909b-45d1991a2876 |
| Battery char | 2adb4877-68d8-4884-bd3c-d83853bf27b8 |
Temperature payload is little-endian uint16 fields:
[0:2] tip raw → tip_c = (raw + 8) / 16
[2:4] ambient raw
[4:6] ambient offset
→ ambient_counts = tip + max(0, ((ra - min(48, oa)) * 16 * 589) // 1487)
→ ambient_c = (ambient_counts + 8) / 16
Battery is uint16 * 10, clamped to 0–100.
Confidence: tip decode is simple and well corroborated across projects —
trust it after one bench check. The ambient decode is an empirical fit that
its original authors flagged as hard to reproduce across tip/ambient
combinations. Treat ambient as advisory. We drive the grill from tip_c only.
Operational limit: a MEATER probe accepts exactly one BLE connection. While the Pi holds it, your phone and the Block cannot see it, and vice versa. Plan on the Pi owning the probe for the duration of a cook.
Before trusting it: put the probe in ice water and boiling water, compare against the MEATER app.
ThermoWorks RFX — implemented, cloud-only
Source: sources/thermoworks.py
RFX probes transmit sub-1 GHz RF to an RFX Gateway, which forwards over WiFi to ThermoWorks Cloud. The probes never speak BLE, so the nRF52840 dongle cannot see them at all.
Implemented against thermoworks-cloud
(a2hill), an unofficial library built from the observed behaviour of the
ThermoWorks web client. Explicitly tested with RFX by its author, and confirmed
working by Home Assistant users through a 24-hour brisket cook.
Licensing: it is GPLv3, so it is an optional extra
(pip install '.[thermoworks]') rather than a core dependency. That keeps the
GPL off this project unless you opt in.
API shape
get_user() -> user.account_id
get_devices(account_id) -> [Device(serial, label, battery, ...)]
get_device_channel(serial, "1") -> DeviceChannel(value, units, last_telemetry_saved, ...)
There is no channel listing endpoint. Channels are discovered by requesting ids 1..9 until one 404s — the same approach the Home Assistant integration takes. We cache the result per device rather than re-probing every cycle, since each attempt is a request against an unofficial API.
The thing that will bite you
ThermoWorks Cloud returns a dead probe's last known value with a perfectly healthy HTTP 200. A probe that fell off an hour ago still reports a temperature, and nothing in the response status hints that anything is wrong.
So a successful fetch tells you nothing about whether the number is current. We
date every reading by the cloud's own last_telemetry_saved / last_seen
timestamp and backdate ProbeReading.timestamp accordingly, so the normal
staleness path measures the age of the measurement rather than the age of our
HTTP request. Readings older than max_cloud_age_s (default 300 s) are dropped
outright.
Without that backdating, the fail-cold policy would never trip for a cloud source, and a jack would sit there confidently displaying an hour-old temperature.
Practical limits
| Polling | 60 s works; the HA integration ships a useless 1800 s default |
| Latency | probe → gateway → cloud → here. Fine for low-and-slow, poor for searing |
| Dependency | your internet is in the loop mid-cook; if it drops, jacks fail cold |
| Free tier | up to 10 cloud devices; 11+ needs a paid plan |
Direct RF — not available
Receiving the sub-1 GHz signal directly with an RTL-SDR would remove both the cloud and the gateway. It was requested in rtl_433 (#3041) in August 2024 and closed with no decoder written. No prior art to build on.
One Home Assistant user noticed the RFX Gateway enumerates as an Espressif device — it is an ESP32, which hints at a possible local API. Nobody has explored it. That is the highest-value lead if the cloud dependency becomes annoying.
Other ThermoWorks families
Not handled by this driver. Node is BLE and would want something shaped like
the MEATER driver. Signals is a different WiFi/cloud device — the same
thermoworks-cloud library covers it, but channel semantics differ.
Combustion Inc — not implemented, but the easiest of the three
Source: sources/combustion.py
The only vendor here with an open published protocol and first-party SDKs: https://github.com/combustion-inc/combustion-documentation
Best-fit for this project for one specific reason: probes broadcast temperatures in BLE advertisements, so you can read them without connecting. That sidesteps MEATER's one-connection-at-a-time problem entirely — the Pi can listen while your phone stays connected to the same probe.
Notes to verify against the spec before implementing:
- Service UUID
00000100-CAAB-3792-3D44-97AE51C1407A - 8 temperature sensors (T1 tip → T8 handle), packed as 8 × 13-bit LE = 13 bytes
celsius = raw * 0.05 - 20- Use the virtual core sensor, not raw T1 — core is Combustion's corrected food temperature, T1 is just the physical tip
Deliberately left raising NotImplementedError rather than shipping a parser
written from memory. A 13-bit unpack that's off by one bit boundary produces
confident garbage, and the grill acts on these numbers.
The wireless Traeger probes — the road not taken
Documented so it isn't re-litigated later.
The 2022 Ironwood also supports "Traeger Wireless Meat Probes", which are rebranded MEATER hardware — Traeger acquired Apption Labs (MEATER) in 2021. But Traeger deliberately changed the pairing: plain MEATER probes will not pair to an Ironwood, and Traeger probes will not pair to the MEATER app. That is an intentional auth/whitelist boundary, not an accident.
Reasons this project drives the wired jacks instead:
- It's a real auth boundary. The cross-pairing block is deliberate, so expect challenge-response, not just a different service UUID.
- Firmware updates. A wired PT1000 is a physical standard; a BLE pairing handshake is a moving target Traeger can change at will.
- One dongle can't MITM. A true man-in-the-middle needs two radios — one central to the real probe, one peripheral to the grill. A single nRF52840 is one radio. You'd need two dongles, or the Pi's onboard BLE as the second side.
- MITM was never the goal anyway. Sitting between a real Traeger probe and the grill only relays temperatures you already have. To inject your probes you want emulation, and emulation is exactly what the wired jack gives you for free.
If you ever do revisit it, the nRF52840 dongle's real job there is nRF Sniffer for BLE — capture a genuine probe pairing to Wireshark and start from the handshake.
In the meantime the dongle earns its place as the BLE central for your third-party probes, with a better antenna than the Pi's onboard radio.