# Copy to config.yaml and edit. # # Start with the simulator source and --dry-run to exercise the pipeline with # no hardware at all, then swap in real sources once probes are talking. # # Find your probe ids with: smokescreen discover update_interval_s: 2.0 # how often the jacks are re-driven i2c_bus: 1 # /dev/i2c-1 on a Raspberry Pi log_level: INFO sources: # Synthetic cook curve. Safe to leave in while developing; remove for real cooks. - type: simulator probe_count: 2 speed: 60 # 60x realtime, so a brisket runs in minutes # ThermoWorks RFX, via ThermoWorks Cloud (there is no local gateway API). # Needs: pip install '.[thermoworks]' # Credentials come from THERMOWORKS_EMAIL / THERMOWORKS_PASSWORD in the # environment. Prefer that over putting them here — config.yaml is gitignored, # but it is still one `git add -f` away from being committed. # - type: thermoworks # poll_interval_s: 60 # 60s is what works in practice; faster just burns # # requests against an unofficial API # max_cloud_age_s: 300 # drop cloud values older than this, since the API # # serves a dead probe's last value with a 200 # MEATER / MEATER 2. Remember the probe accepts only ONE BLE connection -- # the Pi cannot read it while your phone or the Block is connected. # Needs: pip install '.[ble]' # - type: meater # display_name: "Brisket point" # address: null # null = scan and take the first probe found # Not implemented yet -- see the module docstring for what it needs. # - type: combustion jacks: 1: # Pin a specific probe here once you know its id. With more probes than # jacks (4 RFX probes, 2 jacks) pinning is how you choose which two matter. # Omit to auto-assign the first probe seen. # probe_id: "thermoworks:RFX123456:1" i2c_address: 0x2f # Must comfortably exceed your slowest source's poll interval, or the jack # flaps cold between polls. Rule of thumb: 3x. For 60s cloud polling use # 180s+; for BLE sources 30s is fine. stale_after_s: 180 # Replace with output from: smokescreen calibrate ... calibration: r_offset_ohms: 1000.0 step_ohms: 1.0 2: # probe_id: "thermoworks:RFX654321:1" i2c_address: 0x2c # second rheostat MUST be strapped to a different address stale_after_s: 180 calibration: r_offset_ohms: 1000.0 step_ohms: 1.0